HiKvision DS-6101HFI-IP-A

CathexisVision Camera Integration
Driver:


  Datasheet
Unicast  
Number Of Streams : 2
Format : H264/MJPEG
Audio : Not Supported
Resolution : 4CIF, 2CIF, 528×320, CIF, QCIF
Multicast  
  Yes (See Limitations)
Motion Detection  
Trigger Zones: 1 Trigger Zone (See limitations)
Trigger String: STARTMOTION_Z1
I/O  
Inputs :  1
Outputs : 1
Settings  
Serial Port : Not Supported
PTZ Control :  Not Supported
Cathexis Software : CatVision 2014 and later
Camera Firmware : V2.0 120423
Limitations :

    • A camera Reboot is required in order for certain camera functions to take effect.
    • A typical camera reboot takes between 50-60 seconds.
    • Multicast will work but the camera only streams to port 8602 and not the configured port.
    • Therefore it may be possible to to use the multicast functionality by configuring the multicast UDP port to 8602.
    • When setting VMD, it is also important to set the “Deployment time” along with ticking “Trigger alarm output” under “Linkage”.
    • The VMD on this encoder is very poor.

 

Cathexis Integrations